Product Description
FARCO LEVEL FLEX is a high modulus, moisture curing, self leveling, and one component sealant based on polyurethane.
Download the catalog
Product Description
FARCO LEVEL FLEX is a high modulus, moisture curing, self leveling, and one component sealant based on polyurethane.
Standard Compliance
- ASTM C 920 , TYPE S, GRADE P, CLASS 25
- TT- S – 00230 C , TYPE I , CLASS A
- ISO 11600 –F-25LM
Technical Data
Base Polyurethane |
Consistency Pourable paste Curing |
system Misture curing |
Density 1.25 g/ml |
Shrinking none |
Shore-A hardness 35° (3sec-ISO868) |
Application temperature range +5°c to +30°c |
Temperature resistance -30°c to +90°c |
Tack free time 60min (23°c, 50% R.H.) |
Curing speed 2mm/day (23°c, 50% R.H.) |
Elongation at break 300% (ISO 37) |
E- Modulus at 100% 0.5Mpa (ISO 37) |
Uses
- Dilatation joints in industrial floors
- Horizontal tile joints and filling of floor cracks
- Horizontal joints in warehouses, factories, parkings, terraces, roof works, road works and tanks
Advantages
- Very easy application
- Suitable for all climates
- Bubble – free curing, no yellowing
- Resist permanent deformation
- Excellent resistance to abrasion
- Exceptional resistance to water, UV-Rays, corrosive environments
- Very good resistance to acids and petroleum-based hydrocarbons
- Stays elastic after curing.
Method of use Surface preparation
- Joint walls must be sound, clean, dry, and free from oil and grease. Curing compound residues and any other foreign matter must be thoroughly removed, install bond breaker to prevent bond at the base of joint.
- Priming is not usually necessary. Most substrates only require priming if testing indicates a need or where sealant will be subjected to water immersion after cure.
- New concrete must be minimum of 28 days old.
- Substrates must be dry; application in wet or damp joints will cause bubbling of the material
Mixing
FARCO LEVEL FLEX is a one component and requires no pre-blending. It should be used directly from the container.
Application
- For good performance, it is essential that the sealant is only bonded to the two facing sides of the joint to achieve this, install a backup material (closed cell polyethylene or open cell polyurethane foam).
- Apply the sealant in a continuous operation making sure all air pockets or voids are eliminated. Tool the sealant with light pressure to spread the material against the joint surfaces.
- This operation should be made with dry spatula before skin formation occurs.
Cleaning
Material: Immediately with solvent Hardened sealant: can only be removed mechanically Hands: soap and water
Curing FARCO LEVEL
FLEX requires no special curing.
Joint Dimensions
Joint width should be 4 times the expected joint movement, the depth of the sealant should be ½ the width of the joint material. The maximum depth is 15 mm. Installation of FARCO LEVEL FLEX deeper than what is recommended can cause bubbling or incomplete curing of the material.
Minimum depth: 6mm
Maximum depth: 15mm
Minimum width: 6mm
Maximum width: 30mm
Coverage
Meter per 600ml foil bag | M. liter per
meter |
Joint size
(mm) |
16.66 | 36 | 6×6 |
10 | 60 | 10×6 |
7.7 | 78 | 13×6 |
3 | 200 | 20×10 |
2 | 300 | 25×12 |
1.33 | 450 | 30×15 |
Limitations
- Use only at temperatures above 4°c.
- Avoid exposure to high levels of chlorine.
- Avoid contact with alcohol and other solvent cleaners during cure.
- Do not cure in the presence of curing silicone sealant.
- Do not apply in or damp joints, as this can cause bubbling within the sealant.
Packaging
FARCO LEVEL FLEX is supplied in 600 ml foil bags.
Storage
FARCO LEVEL FLEX in dry condition at temperatures between 5°c to 30°c.
Shelf life
12 month in original closed packing
Safety and Handling Precautions
Apply the usual industrial hygiene.
Prevent contact with skin, eyes or clothing. Wash thoroughly after handling. Do not take internally.
Technical Service
The SHIMISAKHTEMAN Technical Service Department is available to assist you in the correct use of our products in the field.